Key result
Intracoronary OCT detected more vessel dissections (8 vs 2), tissue prolapse (29 vs 12), and incomplete apposition (7 vs 3) than IVUS across 42 stents.
Observational (n=39)
Answers are grounded in this paper and cite their sources.
BACKGROUND: Conventional contrast cineangiography and intravascular ultrasound (IVUS) provide a limited definition of vessel microstructure and are unable to evaluate dissection, tissue prolapse, and stent apposition on a size scale less than 100 micro m. OBJECTIVE: To evaluate the use of intravascular optical coherence tomography (OCT) to assess the coronary arteries in patients undergoing coronary stenting. METHODS: OCT was employed in patients having percutaneous coronary interventions. Images were obtained before initial balloon dilatation and following stent deployment, and were evaluated for vessel dissection, tissue prolapse, stent apposition, and stent asymmetry. IVUS images were obtained before OCT, using an automatic pull back device. RESULTS: 42 stents were imaged in 39 patients without complications. Dissection, prolapse, and incomplete stent apposition were observed more often with OCT than with IVUS. Vessel dissection was identified in eight stents by OCT and two by IVUS. Tissue prolapse was identified in 29 stents by OCT and 12 by IVUS; the extent of the prolapse (mean (SD)) was 242 (156) microm by OCT and 400 (100) microm by IVUS. Incomplete stent apposition was observed in seven stents by OCT and three by IVUS. Irregular strut separation was identified in 18 stents by both OCT and IVUS. CONCLUSIONS: Intracoronary OCT for monitoring stent deployment is feasible and provides superior contrast and resolution of arterial pathology than IVUS.
No takes yet. Share an insight, caveat, or question.
Brett E. Bouma (2003) conducted an observational in Coronary artery disease undergoing percutaneous coronary intervention and stenting (n=39). Intravascular optical coherence tomography (OCT) vs. Intravascular ultrasound (IVUS) was evaluated on Identification of tissue prolapse, vessel dissection, and incomplete stent apposition. Intracoronary OCT detected more vessel dissections (8 vs 2), tissue prolapse (29 vs 12), and incomplete apposition (7 vs 3) than IVUS across 42 stents.
Synapse has enriched 10 related papers. Consider them for comparative context: