Answers are grounded in this paper and cite their sources.
We measured the bone mineral content (BMC) of 21 human femoral autopsy specimens using Radiographic Attenuation Technique (RAT). The specimens were then tested for stiffness in a material-testing machine. Osteosynthesis was performed after medial femoral neck osteotomy, using 1 of 3 different pinning methods: 2 hook pins (LIH), 2 cannulated screws (Uppsala), and 3 cannulated screws (CHP). The specimens were allocated to each method by grouping them in triplets with similar BMC. Cyclic loading at 500-1000 N and 1 Hz was performed during 50 minutes. The amount of axial compression during loading was measured. Finally, loading to failure was done and post-fixation stiffness and ultimate compression strength recorded. With one exception, all cases failed where the BMC was less than 0.4 g/cm2. No differences between the methods of osteosynthesis were found. The fixation strength was mostly dependent on the strength of the bone, i.e., the degree of osteoporosis.
No takes yet. Share an insight, caveat, or question.
Zetterberg et al. (1994) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: