Why the study?
Tissue temperature determines lesion creation during RF ablation, but is difficult to measure during conventional ablation due to high-flow saline irrigation.
Does a temperature-controlled irrigated RF ablation system safely and effectively treat sustained monomorphic VT in patients with structural heart disease?
Does a temperature-controlled irrigated RF ablation system safely and effectively treat sustained monomorphic VT in patients with structural heart disease?
A novel temperature-controlled irrigated RF ablation system demonstrated 100% acute procedural success and no 30-day serious adverse events in patients with monomorphic VT and structural heart disease.
Answers are grounded in this paper and cite their sources.
Temperature-modulated irrigated RF ablation appears feasible in VT; hypothesis-generating and requires randomized validation before adoption.
BACKGROUND: Catheter ablation using radiofrequency (RF) energy is an established treatment for ventricular tachycardia (VT). Tissue temperature is a key determinant of successful lesion creation, and yet, it is difficult to measure during conventional RF ablation because of the cooling effect of high-flow rate saline irrigation. The TRAC-VT study evaluated the safety and efficacy of a novel irrigated RF ablation system modulating power based on real-time tissue temperature. METHODS: Patients with sustained monomorphic VT and structural heart disease (SHD) were enrolled. Catheter ablation was performed in temperature-control mode (irrigation 8 ml/min, temperature set-points 55 or 60 °C, and power output ≤ 50 W), with RF applications for ≤ 45 s. The primary safety endpoint was a composite of cardiovascular-specific serious procedure-related adverse events within 30 days post-ablation. The primary effectiveness endpoint was acute success (i.e., non-inducibility of all clinically relevant VTs). RESULTS: Thirty-eight patients were enrolled with monomorphic VT (age 68 ± 12 years and 84% male), with an average of 1.7 ± 1.2 VTs targeted per patient. In total, 41 ± 23 RF applications per patient were delivered. Acute procedural success was 100% (95% CI, 91-100%). No primary safety endpoints were observed. Six-month follow-up was completed in 92% of patients with 81% (95% CI, 65-91%) freedom from sustained or treated VT. A repeat ablation was performed in three patients. CONCLUSIONS: Ablation of VT in SHD, using a temperature-controlled irrigated RF catheter, was safe and effective with a low rate of VT recurrence at 6 months.
No takes yet. Share an insight, caveat, or question.
Kautzner et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: