We present a cavity resonance-enabled wireless power transfer (CR-WPT), in which the resonant frequency can be adjusted using a monopole probe with a reactance circuit (reactance probe). CR-WPT has attracted considerable attention as a technology that makes highly efficient power transmission possible out of line of sight. However, the resonant frequency fluctuates because the equipment is installed and moved inside the cavity; thus, the transmission frequency must be adjusted accordingly. This paper addresses this issue through simulation and demonstration by developing a method for adjusting the resonant frequency with a reactance probe while keeping the power transmission frequency fixed. The resonant frequency can be controlled according to the amplitude of the electric field in the cavity and the length and number of probes. In an 890 × 1750 × 1820-mm cavity, a resonant frequency of 417.5 MHz was set as the power transmission frequency in TE015mode, and a frequency shift of 3.7 MHz occurred when a work robot was installed and moved inside. The resonant frequency was restored to its original value by installing five reactance probes with a physical length of 180 mm and a −30.7-Ω reactance circuit. This provided a stable power supply to the sensors mounted on the robot and to the surrounding power-receiving modules without changing the power transmission frequency. This proof-of-principle demonstration is a major step toward the practical application of CR-WPT.
No takes yet. Share an insight, caveat, or question.
Masaya Tamura (2025) studied this question.