Answers are grounded in this paper and cite their sources.
Volatile organic compounds (VOCs) emitted into headspace over discrete electronic components including resistors, capacitors, diodes, transistors, and transformers were identified and quantitatively determined in Part 1 of this series using gas chromatography/mass spectrometry. Vapors emissions of VOCs were characteristic of each component and headspace concentrations increased with temperature and persisted with time in most instances. Technology suitable for routine continuous monitoring of air quality based on gas chromatography/differential mobility spectrometry (GC/DMS) was evaluated with the same electronic components here, Part 2 of this series. Distinctive patterns in plots of ion peak intensity, retention time, and compensation voltage were obtained from VOCs from resistors, capacitors, and insulation from wires of a transformer held at 200°C for ten minutes. Intensity of response and analytically rich information produced by GC/DMS suggest further utility also as an air quality monitor or smart smoke alarm with electronics-dense habitats in spacecraft or offices and industrial venues.
No takes yet. Share an insight, caveat, or question.
A 2014 study studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: