Why the study?
Does treadmill exercise stress echocardiography detect HFpEF in high-fat diet fed type-2 diabetic ALDH2*2 mutant mice?
Does treadmill exercise stress echocardiography detect HFpEF in high-fat diet fed type-2 diabetic ALDH2*2 mutant mice?
Treadmill exercise stress echocardiography can unmask HFpEF in a diabetic ALDH2*2 mutant mouse model that exhibits preserved systolic function at rest.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Exercise stress echocardiography may unmask systolic dysfunction in diabetic ALDH2*2 mice; leaves open translation to human HFpEF.
E487K point mutation of aldehyde dehydrogenase (ALDH) 2 (ALDH2*2) in East Asians intrinsically lowers ALDH2 activity. ALDH2*2 is associated with diabetic cardiomyopathy. Diabetic patients exhibit heart failure of preserved ejection fraction (HFpEF) i.e. while the systolic heart function is preserved in them, they may exhibit diastolic dysfunction, implying a jeopardized myocardial health. Currently, it is challenging to detect cardiac functional deterioration in diabetic mice. Stress echocardiography (echo) in the clinical set-up is a procedure used to measure cardiac reserve and impaired cardiac function in coronary artery diseases. Therefore, we hypothesized that high-fat diet fed type-2 diabetic ALDH2*2 mutant mice exhibit HFpEF which can be measured by cardiac echo stress test methodology. We induced type-2 diabetes in 12-week-old male C57BL/6 and ALDH2*2 mice through a high-fat diet. At the end of 4 months of DM induction, we measured the cardiac function in diabetic and control mice of C57BL/6 and ALDH2*2 genotypes by conscious echo. Subsequently, we imposed exercise stress by allowing the mice to run on the treadmill until exhaustion. Post-stress, we measured their cardiac function again. Only after treadmill running, but not at rest, we found a significant decrease in % fractional shortening and % ejection fraction in ALDH2*2 mice with diabetes compared to C57BL/6 diabetic mice as well as non-diabetic (control) ALDH2*2 mice. The diabetic ALDH2*2 mice also exhibited poor maximal running speed and distance. Our data suggest that high-fat fed diabetic ALDH2*2 mice exhibit HFpEF and treadmill exercise stress echo test is able to determine this HFpEF in the diabetic ALDH2*2 mice.
Pan et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: