The technique of deep-level capacitance spectroscopy was applied to a number of nitrogen-doped level VPE GaP samples. The thermal emission energies and electron and hole capture cross sections were determined for a dozen deep levels. Using these cross sections along with the measured defect concentrations, high excitation density and low-excitation-density minority-carrier lifetimes are calculated. These calculated values are at least one order of magnitude large than lifetimes determined from optical and SEM techniques. cross sections were determined for a dozen deep levels. Using these cross sections along with the measured defect concentrations, high excitation density, and low-excitation-density minority-carrier lifetimes are calculated. These calculated values are at least one order of magnitude larger than lifetimes determined from optical and SEM techniques.
No takes yet. Share an insight, caveat, or question.
Tell et al. (1978) studied this question.