We Present detailed measurements of the electron-avalanche process in liquid xenon. The measurements were made by using liquid-xenon-filled proportional chambers with anode diameters of 2.9, 3.5, and 5.0 {μ} to detect 279-keV γ rays and measure the photopeak pulse height as a function of applied voltage. The use of uniform pulses of electrons enabled us to discriminate against secondary Townsend processes. We present a table of the first Townsend coefficient α as a function of electric field E; a typical value is α=(4.5±0.3)×10⁴ cm^-1 at E=2×10⁶ V/cm. The electron avalanche occurs in liquid xenon at electric fields 27 ±{} 3 times smaller than would be predicted using measurements made in gaseous xenon and Eρ density scaling.
No takes yet. Share an insight, caveat, or question.
Derenzo et al. (1973) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: