Why the study?
Can a one-dimensional MR sequence rapidly and accurately measure aortic wave velocity in vivo?
Can a one-dimensional MR sequence rapidly and accurately measure aortic wave velocity in vivo?
A one-dimensional MR sequence can rapidly measure aortic wave velocity in vivo, demonstrating expected age-related hemodynamic changes.
Answers are grounded in this paper and cite their sources.
Supports rapid 1D MR aortic wave velocity measurement; leaves open prospective validation against references and clinical utility.
The utility of a one-dimensional magnetic resonance (MR) sequence to rapidly and accurately measure wave velocity in vivo was evaluated. Studies were conducted in the thoracic aortas of 20 healthy subjects of varying age, and the MR method was validated in a compliant tube model. Aortic wave velocity ranged from 3.8 to 9.7 m/sec and demonstrated a positive correlation with subjects' age. Peak blood velocity ranged from 47 to 125 cm/sec and exhibited a strong negative correlation with subjects' age.
No takes yet. Share an insight, caveat, or question.
Itskovich et al. (2001) studied this question.