Why the study?
To evaluate the safety and efficacy of a novel vascular-friendly thoracic stent graft for patients with acute complicated type B aortic dissection.
Does thoracic endovascular aortic repair with the Ankura Thoracic Stent improve outcomes in patients with acute complicated type B aortic dissection?
Does thoracic endovascular aortic repair with the Ankura Thoracic Stent improve outcomes in patients with acute complicated type B aortic dissection?
TEVAR with the Ankura Thoracic Stent for acute complicated type B aortic dissection is associated with low mortality, acceptable complication rates, and improved true lumen rates.
Answers are grounded in this paper and cite their sources.
Supports Ankura TEVAR feasibility in acute complicated TBAD; leaves open randomized confirmation of durability and broader adoption.
PURPOSE: To evaluate the safety and efficacy of a novel vascular-friendly thoracic stent graft for patients with acute complicated type B aortic dissection (ac-TBAD). METHODS: A multicenter retrospective study was undertaken in which we prospectively collected data in consecutive ac-TBAD patients treated by thoracic endovascular aortic repair (TEVAR) with the Ankura Thoracic Stent. Complications, true lumen rate (TLR), and mortality were recorded. Follow-up computed tomography angiography (CTA) was performed at 1, 6, and 12 months postoperatively and yearly thereafter. RESULTS: Altogether, 63 patients with ac-TBAD in four medical centers were included. No deaths or serious complications occurred during the perioperative period. The mean follow-up time was 30.1 ± 18.9 months. All-cause mortality rate was 3.1% (n = 2). TEVAR-related mortality rate was 1.6% (n = 1) because of retrograde type A dissection (RTAD) at 6 months. The other death was caused by acute myocardial infarction (AMI) during the third postoperative month. A distal endoleak detected at 3 months in one patient (1.6%) was treated by reintervention. The use of this novel vascular-friendly thoracic stent graft in ac-TBAD postoperative patients significantly improved their TLR. CONCLUSION: The novel vascular-friendly thoracic stent graft showed satisfactory results, with favorable stability of the aortic diameter during follow-up.
No takes yet. Share an insight, caveat, or question.
Jin et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: