Why the study?
Current anatomical mapping methods for identifying structural substrates in real time to locate ablation sites during radiofrequency ablation for atrial fibrillation are limited.
Does a 7F NIRS integrated ablation catheter accurately identify endocardial substrates and predict lesion depth in ex vivo left atrial tissue?
Does a 7F NIRS integrated ablation catheter accurately identify endocardial substrates and predict lesion depth in ex vivo left atrial tissue?
A novel NIRS-integrated ablation catheter accurately identifies endocardial substrates and predicts lesion depth in ex vivo models, suggesting potential utility for improving radiofrequency ablation guidance.
Supports NIRS catheter feasibility ex vivo; leaves open in vivo human validation before clinical adoption.
Atrial fibrillation (AF) is a rapid irregular electrical activity in the upper chamber and the most common sustained cardiac arrhythmia. Many patients require radiofrequency ablation (RFA) therapy to restore sinus rhythm. Pulmonary vein isolation requires distinguishing normal atrial wall from the pulmonary vein tissue, and atrial substrate ablation requires differentiating scar tissue, fibrosis, and adipose tissue. However, current anatomical mapping methods for strategically locating ablation sites by identifying structural substrates in real-time are limited. An intraoperative tool that accurately provides detailed structural information and classifies endocardial substrates could help improve RF guidance during RF ablation therapy. In this work, we propose a 7F NIRS integrated ablation catheter and demonstrate endocardial mapping on ex vivo swine (n = 12) and human (n = 5) left atrium (LA). First, pulmonary vein (PV) sleeve, fibrosis and ablation lesions were identified with NIRS-derived contrast indices. Based on these key spectral features, classification algorithms identified endocardial substrates with high accuracy (<11% error). Then, a predictive model for lesion depth was evaluated on classified lesions. Model predictions correlated well with histological measurements of lesion dimensions (R = 0.984). Classified endocardial substrates and lesion depth were represented in 2D spatial maps. These results suggest NIRS integrated mapping catheters can serve as a complementary tool to the current electroanatomical mapping system to improve treatment efficacy.
No takes yet. Share an insight, caveat, or question.
A 2022 study studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: