Adjustable Speed Drives (ASDs) with diode bridge front end usually employ a capacitor (C) in the DC-link and an inductor either in the AC side or in the DC link. Proper design of DC link is essential to attenuate the input current harmonics and DC link ripple, and support the intermediate energy requirement by the inverter. The ripple in the DC link may further impact the motor speed/torque oscillations. Due to the increase in grid disturbances, it is necessary to consider their effects in the design phase of the DC link filter of ASD. This paper proposes a method to identify an optimal value for DC link parameters considering the grid disturbances in order to achieve a lesser stress in the DC link capacitor. Effectiveness of the proposed method in identifying an optimum DC link parameter value is shown for a 7.5 kW ASD considering different grid disturbances based on field data collected at different industrial sites.
No takes yet. Share an insight, caveat, or question.
Gopalan et al. (2025) studied this question.