The horizontally scanning, multi-angle charge-exchange analyser on the Poloidal Divertor Experiment (PDX) was used to study the beam ion slowing-down process with high-power perpendicular injection. Measurements were made over a wide range in toroidal field (8 kG <B T <22 kG), plasma current (200 kA <I p <500 kA), and beam power (1 MW <P B <7 MW). In MHD-quiescent plasmas, agreement is found between the measured slowing-down spectra and theoretical predictions as a function of both angle and energy. Classes of prompt orbit losses are observed with both co-and counter-injection which have been understood and applied to plasma diagnostics.