Why the study?
Does self-management using a home monitoring device for INR improve outcomes and accuracy in patients who require long-term anticoagulation treatment compared to standard practice?
Does self-management using a home monitoring device for INR improve outcomes and accuracy in patients who require long-term anticoagulation treatment compared to standard practice?
Answers are grounded in this paper and cite their sources.
Point-of-care INR self-management is as accurate as laboratory testing and significantly reduces thromboembolic events and mortality compared to standard clinic-based care.
In patients who require long-term anticoagulation treatment, how accurate and effective is self-management using a home monitoring device for INR, compared to standard practice?
No takes yet. Share an insight, caveat, or question.
Plüddemann et al. (2012) conducted a review in Long-term oral anticoagulation therapy. Self-management and self-monitoring of INR using point-of-care coagulometers vs. Standard clinic-based care was evaluated on Thromboembolic events (HR 0.51, 95% CI 0.31 to 0.85).
Synapse has enriched 10 related papers. Consider them for comparative context: