Answers are grounded in this paper and cite their sources.
The adsorption of Cl2 on Cu{111} at 300 K has been studied using shadow-cone-enhanced secondary ion mass spectrometry (SIMS). The system has been investigated for chlorine coverages ranging from 0.08 to 0.33 monolayer (ML), including the Cu{111}-(√3×√3)R30°-Cl surface. The secondary Cu+ ion intensity has been measured as a function of the incidence angle of the primary ion beam. The enhanced intensity features in the spectra are compared with results from a two-body interaction calculation that uses the Molière approximation to the Thomas–Fermi potential. A chlorine–copper interlayer spacing of 1.87±0.04 Åis measured between the coverages of 0.17 and 0.33 ML. This value corresponds to a chlorine–copper bond length of 2.38±0.04 Å. At 0.08 ML, the chlorine–copper bond length is expanded to 2.48±0.04 Å. These results suggest that the chlorine–copper bond is more ionic in the low coverage limit.
No takes yet. Share an insight, caveat, or question.
Way et al. (1996) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: