This is the authors' abstract. We don't add key points for this paper.
The authors consider the detection of cracks appearing close to the rivets in ageing riveted lap joints of aircraft structures, using the eddy current (EC) technique. As the presence of the rivets perturbs the interpretability of the defect EC signatures, the authors propose to fuse the data provided by oriented field EC sensors used in different operating modes. Different fusion rules are considered and the performances of defect detection are then characterized with receiver operating characteristic curves.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Joubert et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: