The effects of annealing temperature on the magnetic properties of consolidated Fe-Al-Ga-P-C-B-Si glassy alloy prepared by the pulse-current-sintering method were investigated. A high relative density of 99% combined with good soft magnetic properties was obtained for a sintering temperature of 703 K in the as-sintered state. The flux density under an applied field of 800 A/m (B800), relative permeability at f=1 kHz (μ'1 kHz), and core loss at f=50 Hz and Bm=0.5 T (W5/50) for the sample sintered at 703 K in the as-sintered state were 1.08T, 1,700, and 0.2 W/kg, respectively. B800,μ'1 kHz, and W5/50 were improved to 1.17 T, 2,500, and 0.11 W/kg by annealing at 723K for 3.6ks. It is considered that these improvements were due to stress relaxation of the consolidating process originating in structural relaxation of the amorphous structure.
No takes yet. Share an insight, caveat, or question.
Yōshida et al. (2001) studied this question.