Answers are grounded in this paper and cite their sources.
The spatial distribution of the neutral source profile is an important quantity for the understanding of the pedestal density profile and effects like its influence on rotational shear by momentum exhange.Analytic models as well as numerical predictive codes require experimental data on the magnitude and poloidal distribution of the neutral flux density in order to be validated.This paper describes the measurement and interpretation of D α radiance data obtained with a pair of tangentially viewing cameras at the ASDEX Upgrade tokamak.Reflection at the tungsten tile surfaces covering most of the tokamak wall is an issue to be addressed in the procedures for data analysis.Besides a simple profile fit, a reflection-aware algorithm for tomographic reconstruction is adopted for radiance deconvolution.Results for the neutral flux density distribution at the high-field side (HFS) are presented for low and medium density scenarios, based on the comparison of experimental emission profiles and those obtained by the neutral penetration code KN1D.Absolute values for flux densities at the HFS separatrix are interpreted in terms of SOL parameters and the extension of the plasmawall gap.A number of examples characterises the D α video diagnostics as a valuable tool to supply estimates on neutral parameters.
No takes yet. Share an insight, caveat, or question.
Harhausen et al. (2010) studied this question.