This is the authors' abstract. We don't add key points for this paper.
INTRODUCTION: A cohort of Gulf War I veterans who sustained exposure to depleted uranium undergoes biennial surveillance for potential uranium-related health effects. We performed impulse oscillometry and hypothesized that veterans with higher uranium body burdens would have more obstructive abnormalities than those with lower burdens. METHODS: We compared pulmonary function of veterans in high versus low urine uranium groups by evaluating spirometry and oscillometry values. RESULTS: Overall mean spirometry and oscillometry resistance values fell within the normal ranges. There were no significant differences between the high and low uranium groups for any parameters. However, more veterans were classified as having obstruction by oscillometry (42%) than spirometry (8%). CONCLUSIONS: While oscillometry identified more veterans as obstructed, obstruction was not uranium-related. However, the added sensitivity of this method implies a benefit in wider surveillance of exposed cohorts and holds promise in identifying abnormalities in areas of the lung historically described as silent.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Hines et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: