Answers are grounded in this paper and cite their sources.
Ammonia (NH 3 ) is an important, albeit sticky, precursor for producing secondary inorganic aerosols (SIA), especially in the form of ammonium nitrate (NH 4 NO 3 ) and ammonium sulfate ((NH 4 ) 2 SO 4 ). To reduce SIAs, many researchers have attempted to measure the concentration of ambient NH 3 using real-time or passive methods. However, NH 3 is a highly sticky gas and is therefore difficult to measure using real-time methods without incurring losses during measurement. In this study, four different tubing materials, semi seamless tubes, perfluoroalkoxy (PFA), polytetrafluoroethylene (PTFE), and polyvinylidene fluoride (PVDF), were used to ascertain the adsorption of NH 3 in inlets using real-time instruments. Without heating sample tubes and at 0% relative humidity (RH), this study shows that PTFE had the least adsorption(i.e., 0% at 1 and 2m of sample tube), and semi-seamless tubes had the highest adsorption (i.e., 27.5% at 1 m of sample tube). To calculate the adsorption of NH 3 under ambient conditions, at various inlet lengths, the RH of NH 3 was varied from 20% to 80%, which showed that shorter inlets and higher RH lower NH 3 adsorption at inlets (i.e., 1.74 ppb m −1 at 80% RH and 7.48 ppb m −1 at 20% RH). Additionally, inlet heating was effective in reducing the adsorption of NH 3 as the RH decreased. Applying the inlet system (i.e., 2 m of PTFE tube with heating) showed excellent correlation (slope: 0.995 and coefficient: 0.992) between two different real-time measurements while measuring ambient air.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: