Nanoscale-topography PNIPAAm surfaces resist platelet adhesion across temperatures unlike smooth surfaces.
Answers are grounded in this paper and cite their sources.
Nanoscale topography was constructed on a thermally responsive poly(N-isopropylacrylamide) (PNIPAAm) surface by grafting the polymer from silicon nanowire arrays via surface-initiated atom transfer radical polymerization. The as-prepared surface showed largely reduced platelet adhesion in vitro both below and above the lower critical solution temperature (LCST) of PNIPAAm ( approximately 32 degrees C), while a smooth PNIPAAm surface exhibited antiadhesion to platelets only below the LCST. Contact angle and adhesive force measurements on oil droplets (1,2-dichloroethane) in water demonstrated that the nanoscale topography kept a relatively high ratio of water content on the as-prepared surface and played a key role in largely reducing the adhesion of platelets; however, this effect did not exist on the smooth PNIPAAm surface. The results can be used to extend the applications of PNIPAAm in the fields of biomaterials and biomedicine under human physiological temperature and provide a new strategy for fabricating other blood-compatible materials.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2009) studied this question. Poly(N-isopropylacrylamide) (PNIPAAm) surface with nanoscale topography vs. Smooth PNIPAAm surface was evaluated on In vitro platelet adhesion. Nanoscale-topography PNIPAAm surfaces reduced platelet adhesion in vitro both below and above the ~32°C LCST, whereas smooth PNIPAAm resisted adhesion only below ~32°C.