Why the study?
Does TEE monitoring of left ventricular wall motion correspond to PAC-derived hemodynamic data during low-dose dobutamine stress in patients undergoing CABG?
Does TEE monitoring of left ventricular wall motion correspond to PAC-derived hemodynamic data during low-dose dobutamine stress in patients undergoing CABG?
Visual assessment of improved left ventricular wall motion using TEE corresponds with increased stroke volume measured by PAC during dobutamine stress, suggesting TEE could substitute PAC for quick estimation of LV performance.
TEE wall motion may align with PAC hemodynamics during dobutamine stress in CABG; hypothesis-generating and needs prospective validation before substitution.
BACKGROUND: The clinical acceptance of transesophageal echocardiography (TEE) as a monitoring technique for left ventricular function in open-heart surgery is now widely recognized. This technique's accurate imaging capabilities have been found to improve the information obtained by the pulmonary catheter (PAC) and thermodilution. TEE is also a less invasive technique than PAC. However, because it is costly, further comparisons between the techniques are worthwhile. This study compares hemodynamic data obtained with PAC and how these correspond to echocardiography data using TEE. METHODS: Twenty-four anesthetized patients undergoing elective coronary artery bypass grafting (CABG) were studied. They were monitored with PAC and TEE. A low-dose dobutamine protocol for viability was used with doses of 5 and 10 microg x kg(-1) x min(-1). Endpoints for this stimulation included on-line visual change in left ventricle wall motion (LVWM), increased arterial blood pressure more than 40 mmHg, a heart rate (HR) increase of more than 20%, or ST depression on ECG exceeding 0.2 mV. Visual assessment of LVWM using the transgastric short-axis view was made off line by a blinded observer. Six segments were used and a wall motion score was made at each level of dobutamine stimulation. RESULTS & CONCLUSION: Two patients reached the endpoint for elevated blood pressure with a dobutamine dose of 5 microg x kg(-1) x min(-1), and twenty-two patients were stimulated to 10 microg x kg(-1) x min(-1). There were significant increases in cardiac output (CO), stroke volume (SV), systolic arterial pressure (SAP), mean arterial pressure (MAP), diastolic arterial pressure (DAP), pulmonary capillary wedge pressure (PCWP) and left ventricle stroke work index (LVSWI), but not in HR and systemic vascular resistance (SVR). Moreover, the LVWM increased significantly, but not fractional area change (FAC). The main finding, however, was the increase in SV with an accompanying improvement in LVWM, suggesting that visual assessment of improved wall motion could substitute PAC and thermodilution monitoring in clinical settings which demand a quick estimate of left ventricular performance.
No takes yet. Share an insight, caveat, or question.
Palmgren et al. (2001) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: