Linear system theory techniques were used to predict threshold-voltage shifts for 4007 inverters at dose rates of 270, 49.7, and 0.19 rad(Si)/s, from a transient annealing curve determined following a 5-rad(Si)/s 60Co irradiation. These predictions were compared with threshold-voltage shifts obtained following 60Co irradiations actually performed at these dose rates, and the agreement is excellent. We observed a wide range of annealing rates for commercial and military 4007 inverters--some Al-gate inverters exhibited very little annealing following irradiation, while an Si-gate inverter completely annealed back to its preirradiation threshold voltage in ~5 × 105 s. The radiation responses of 4007's from a specific manufacturer with different packaging (i.e., plastic or ceramic) and/or electrical characterization (i.e., high-reliability or JAN) were found to vary significantly. Maintaining bias following irradiation was determined to be important in characterizing the anneal of both Al-and Si-gate inverters. Finally, dose-enhancement effects on the threshold-voltage shift were observed for 60Co inpool irradiations where the source and sample were separated by 20 in. of water.
No takes yet. Share an insight, caveat, or question.
Winokur et al. (1983) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: