Answers are grounded in this paper and cite their sources.
The work presented in this article focused on the development of a pseudo-3D computational approach for visualizing computational ultrasonic inspection models for thin composite laminates with complex geometry. The approach creates a 3D dataset by merging several 2D models along different cross-sectional slices of the material under inspection. The approach was applied to a 2.6 mm thick carbon fiber epoxy laminate with an annulus-shaped artificial defect concentric with a 4 mm diameter through hole, shadowed by a 100° countersink. Investigations were performed using water immersion ultrasonic pulse-echo and single-sided pitch-catch setups operating at a 5 MHz frequency. Time-of-flight comparisons between computational and experimental A-scans validated the computational results, demonstrating a calibration error of 4%. Defect sizes measured in the C-scans of the computational model matched the actual outer diameter and width of the annulus, with a difference of 18% and 6%, respectively. Findings within the experimental dataset were similar, with the largest difference associated with the defect width being off by 0.088 mm. The pseudo-3D approach revealed that a normal incidence water immersion setup was ineffective in detecting defects from the countersunk geometry, while an oblique incidence inspection at 8.4375° was successful in capturing the defect with reasonable accuracy.
No takes yet. Share an insight, caveat, or question.
Mull et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: