Key result
Terahertz spectroscopy detects rivaroxaban ~40-fold more sensitively than Raman spectroscopy in one minute.
Why the study?
Differences in plasma concentrations of rivaroxaban among thrombosis disease patients complicate dosage selection and plasma concentration control, and conventional detection methods have limitations in accuracy, speed, and cost.
Does terahertz (THz) spectroscopy provide a rapid and sensitive quantitative detection method for rivaroxaban compared to Raman spectroscopy?
Does terahertz (THz) spectroscopy provide a rapid and sensitive quantitative detection method for rivaroxaban compared to Raman spectroscopy?
Answers are grounded in this paper and cite their sources.
Terahertz spectroscopy provides a rapid and highly sensitive analytical method for the quantitative detection of rivaroxaban, demonstrating a significantly lower detection limit compared to Raman spectroscopy.
Rivaroxaban, as a direct oral anticoagulant, has been widely used in the treatment and prevention of thrombosis disease (TD). However, even if the same dose of rivaroxaban is taken, different pathophysiological characteristics of TD patients determine the differences in plasma concentrations between individuals, leading to the difficulties of dosage selection and plasma concentration control. Conventional rivaroxaban detection methods, including prothrombin time method, anti-Xa assay and liquid chromatography-tandem mass spectrometry (LC-MS/MS), are not widely used in clinical practice due to the limitations of accuracy, speed and cost. Here, we present a simple quantitative detection method for rivaroxaban by terahertz (THz) spectroscopy. Combining density functional theory (DFT) method and THz spectroscopy, the THz absorption peaks of rivaroxaban and the corresponding low-frequency vibrational modes are studied theoretically and experimentally. We find linear relationships between the amplitudes of these characteristic peaks and the concentrations of rivaroxaban. Based on these linear functions, we can analyse the rivaroxaban concentration with a detection time of 1 minute per test and the lowest detection limit of 2 μmol mL-1. As compared to Raman spectroscopy method (its detection limit is about 80 μmol mL-1), our method has more potential and is practical for the clinical quantitative detection of rivaroxaban as well as other direct oral anticoagulants.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2020) studied this question. Terahertz (THz) spectroscopy vs. Raman spectroscopy was evaluated on Detection limit and time for quantitative analysis of rivaroxaban concentration. Terahertz spectroscopy enabled rapid quantitative detection of rivaroxaban in 1 minute with a lowest detection limit of 2 μmol/mL, outperforming Raman spectroscopy.
Synapse has enriched 10 related papers. Consider them for comparative context: