Why the study?
Does an optimal left ventricular lead position improve ejection fraction and peak oxygen consumption in patients with heart failure undergoing cardiac resynchronisation therapy?
Does an optimal left ventricular lead position improve ejection fraction and peak oxygen consumption in patients with heart failure undergoing cardiac resynchronisation therapy?
Concordance of the LV lead site with the location of the latest systolic contraction before CRT results in significantly greater improvement in ejection fraction and cardiopulmonary capacity.
Answers are grounded in this paper and cite their sources.
Optimal LV lead position was associated with larger EF and VO2max gains; hypothesis-generating for targeted placement trials.
BACKGROUND: Definition of the optimal left ventricular (LV) lead position in cardiac resynchronisation therapy (CRT) is desirable. OBJECTIVE: To define the optimal LV lead position in CRT and assess the effectiveness of CRT depending on the LV lead position using new myocardial deformation imaging. METHODS: Myocardial deformation imaging based on tracking of acoustic tissue pixels in two-dimensional echocardiographic images (EchoPAC, GE ultrasound) was performed in 47 patients with heart failure at baseline and during CRT. In a 36-segment LV model the segment with the latest peak systolic circumferential strain before CRT was determined. The segment with maximal temporal difference in peak systolic circumferential strain on CRT compared with before CRT was assumed to be the LV lead position. The optimal LV lead position was defined as concurrence or immediate neighbouring of the segment with the latest contraction before CRT and those with assumed LV lead location. RESULTS: 25 patients had optimal and 22 non-optimal LV lead positions. Before CRT, the LV ejection fraction (EF) and peak oxygen consumption (Vo2max) were similar in patients with optimal and non-optimal LV lead positions (mean (SD) EF = 31.4 (6.1)% vs 30.3 (6.5)% and Vo2max = 14.2 (1.8) vs 14.0 (2.1) ml/min/kg, respectively). At 3 months on CRT, EF increased by 9 (2)% vs 5 (3)% and Vo2max by 2.0 (0.8) vs 1.1 (0.5) ml/min/kg in the optimal vs non-optimal LV lead position groups, respectively (both p<0.001). CONCLUSIONS: Concordance of the LV lead site and location of the latest systolic contraction before CRT results in greater improvement in EF and cardiopulmonary workload than the non-optimal LV lead position.
No takes yet. Share an insight, caveat, or question.
Becker et al. (2007) studied this question.