Why the study?
Does training on consented guidelines for image analysis reduce interinstitutional variance in volumetric and flow CMR data in adults with repaired Tetralogy of Fallot?
Does training on consented guidelines for image analysis reduce interinstitutional variance in volumetric and flow CMR data in adults with repaired Tetralogy of Fallot?
Consensus training significantly reduces interinstitutional variance in volumetric CMR data analysis for patients with congenital heart disease.
Answers are grounded in this paper and cite their sources.
Training on guidelines was associated with lower interinstitutional CMR variance; supports standardization efforts but leaves open effects on management.
PURPOSE: To investigate the impact of interinstitutional variance (=interobserver variance between institutions) for volumetric and flow cardiac MR (CMR) data and if training on image reading could improve bias. MATERIALS AND METHODS: In a three-center study, a total of 32 adults with repaired Tetralogy of Fallot and 23 controls underwent CMR using standardized protocols for ventricular volumes/mass (by transverse and short-axis cine-MRI) and pulmonary/aortic blood flow by velocity-encoded MRI (VEC-MRI). Data were analyzed blinded and independently in each institution by experienced readers. Interinstitutional variance was determined before/after training on consented guidelines for image analysis. RESULTS: In patients, initial interinstitutional variability of right ventricular parameters was substantial but decreased by training. On transverse planes, variation coefficient for end-diastolic/systolic volumes and ejection fraction decreased from 22%, 19%, and 19% to 7%, 10%, and 8%, respectively (P < 0.025). Left-ventricular variation coefficients improved for end-diastolic and stroke volumes from 8% and 15% to 4% and 6%, respectively (P < 0.007). For short-axis volumetry training resulted in narrowed limits of confidence. Variability did not significantly change in the controls. There was no significant difference between transverse/short-axis MRI. Interinstitutional variance for VEC-MRI in patients/controls was low (<4%). CONCLUSION: Interinstitutional variance is an important source of variability in volumetric but not in flow CMR. Such variance can be reduced effectively by consented training.
No takes yet. Share an insight, caveat, or question.
Beerbaum et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: