Why the study?
Does MDCT provide a reliable alternative to CMR for measuring systemic right ventricular volumes and function in adult patients with a systemic right ventricle?
Does MDCT provide a reliable alternative to CMR for measuring systemic right ventricular volumes and function in adult patients with a systemic right ventricle?
MDCT provides a reliable alternative to CMR for assessing systemic right ventricular volumes and function in adults with congenital heart disease, though it has slightly higher inter-observer variability for stroke volume.
MDCT shows comparable reproducibility to CMR for most systemic RV measures; leaves open whether higher stroke volume variability affects serial monitoring in congenital heart disease.
Cardiovascular Magnetic Resonance (CMR) imaging is considered the gold standard for volumes and function measurements of the systemic right ventricle (RV). However, 20% of patients with a systemic RV is pacemaker dependent, and unsuitable to undergo CMR. Multidetector Row Computed Tomography (MDCT) could provide a reliable alternative for CMR in these patients. The aim of this study was to compare variability of MDCT with CMR measurements. Thirty-five patients (23 with an atrially switched transposition of the great arteries, and 12 with a congenitally corrected transposition of the great arteries) underwent MDCT (n = 15; 47% male; 32 ± 8 yrs), or CMR (n = 20; 80% male; 35 ± 12 yrs). Systemic RV end diastolic volume, end systolic volume, stroke volume, and ejection fraction were obtained.RV evaluation was done 3 times by 2 independent observers (MW, SR with 2 and 4 years of experience in CMR and MDCT of adult patients with congenital heart diseases, respectively). The first observer analyzed all scans twice, with a minimal interval of 2 weeks between the first and second scan analysis, and blinded to the previous results. The second observer analyzed the scans once, blinded to the results of the first observer. The intra- and inter-observer variability for both modalities were assessed and compared. The Intra- and inter-observer variability data are summarized in Table 1 . We found the intra-, and the inter-observer variability of volumes and function measurements of the systemic RV obtained with MDCT to be higher compared to those obtained with CMR. However, these differences in variability did not reach statistical significance, the only exception being the inter-observer variability of the systemic right ventricular stroke volume (12% with CMR vs. 32% with MDCT; p < 0.01, Figure 1 ). Bland-Altman plots depicting the intra- and interobserver variability between Multidetector Row Computed Tomography, and Cardiovascular Magnetic Resonance. Caption: Bland-Altman plots demonstrating the intra-observer (left side), and inter-observer (right side) variability of right ventricular a). end diastolic volume, b). end systolic volume, c). stroke volume, and d). ejection fraction. On the X-axis the mean value of both measurements, and on the Y-axis the difference between measurements. The Δ represent measurements performed with MDCT, the represents the mean of the differences between MDCT measurements. The represent measurements performed with CMR, the represent the mean of the differences between CMR measurements. MDCT provides a reliable alternative for CMR for volumes and function assessment in patients with a systemic RV, although larger variability between measurements should be taken into account. However, patient selection should be restrictive, to avoid unnecessary exposure to radiation and contrast agents.
No takes yet. Share an insight, caveat, or question.
Winter et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: