Why the study?
Small-amplitude remote photoplethysmography signals are easily compromised by head movements, lighting conditions, and sensor diversities.
Does a cross-verified feature disentangling strategy improve the accuracy of video-based remote physiological measurement compared to existing methods?
Does a cross-verified feature disentangling strategy improve the accuracy of video-based remote physiological measurement compared to existing methods?
A novel cross-verified feature disentangling strategy for video-based remote physiological measurement improves the accuracy of heart rate estimation compared to existing methods.
May advance video-based remote HR monitoring in research; leaves open clinical validation before practice consideration.
Remote physiological measurements, e.g., remote photoplethysmography (rPPG) based heart rate (HR), heart rate variability (HRV) and respiration frequency (RF) measuring, are playing more and more important roles under the application scenarios where contact measurement is inconvenient or impossible. Since the amplitude of the physiological signals is very small, they can be easily affected by head movements, lighting conditions, and sensor diversities. To address these challenges, we propose a cross-verified feature disentangling strategy to disentangle the physiological features with non-physiological representations, and then use the distilled physiological features for robust multi-task physiological measurements. We first transform the input face videos into a multi-scale spatial-temporal map (MSTmap), which can suppress the irrelevant background and noise features while retaining most of the temporal characteristics of the periodic physiological signals. Then we take pairwise MSTmaps as inputs to an autoencoder architecture with two encoders (one for physiological signals and the other for non-physiological information) and use a cross-verified scheme to obtain physiological features disentangled with the non-physiological features. The disentangled features are finally used for the joint prediction of multiple physiological signals like average HR values and rPPG signals. Comprehensive experiments on different large-scale public datasets of multiple physiological measurement tasks as well as the cross-database testing demonstrate the robustness of our approach.
No takes yet. Share an insight, caveat, or question.
Niu et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: