Answers are grounded in this paper and cite their sources.
CONTEXT: Hip abductor muscle weakness is related to many lower extremity injuries. A simple procedure, the Trendelenburg test, may be used to assess hip abductor performance in patient populations. OBJECTIVE: To describe the minimal detectable change (MDC) in pelvic-on-femoral (P-O-F) position of the stance limb during the Trendelenburg test. SETTING: Laboratory. PARTICIPANTS: 45 healthy women (28 +/- 8 years) and 45 healthy men (33 +/- 11 years). MAIN OUTCOME MEASURES: P-O-F position in degrees in single-leg stance. RESULTS: Baseline P-O-F position (hip adduction) was 83 degrees +/- 3 degrees with a range from 76 degrees to 94 degrees. The intratester reliability (ICC3,1) for measurement of P-O-F position using a universal goniometer was 0.58 with a standard error of measurement (SEM) of 2 degrees. The minimal detectable change (MDC) was calculated to be 4 degrees. CONCLUSIONS: If a person's P-O-F position changes less than 4 degrees between measurements, then the P-O-F position is within measurement error and it can be determined that there has been no change in the performance of the hip abductor muscles when examined by the Trendelenburg test.
No takes yet. Share an insight, caveat, or question.
Youdas et al. (2007) studied this question.