Axial-gap permanent magnet (PM) motors have an air gap in the axial direction and produce more torque than conventional radial-gap motors, especially with flat structures. However, eddy-current loss in the magnets cannot be disregarded since axial-gap PM motors generally have a surface permanent magnet (SPM) rotor and an open slot structure. Furthermore, the open slot structure causes large amounts of torque ripple. We report here a method for decreasing the eddy-current loss by mounting a soft magnetic composite (SMC) onto the magnets. We also propose a method for reducing the torque ripple by adjusting both the pole arc angle of the magnets and the spatial phase difference between the two rotors.
No takes yet. Share an insight, caveat, or question.
Takemae et al. (2013) studied this question.