Answers are grounded in this paper and cite their sources.
The energy spectrum and spatial distribution of neutrons emitted by a plasma focus device were measured with nuclear emulsions and scintillation detectors, and the results are reported. The average energy of the D-D neutrons emitted along the axis was shifted ∼500 keV corresponding to an axial center-of-mass velocity of 2 × 108 cm/secfor the reacting deuterons. An 11% anisotropy in the neutron fluxes measured in the forward and radial directions correlates with an axially streaming plasma which is not isotropic; the reacting deuterons collide predominantly in the radial direction. Time-resolved collimation measurements of the emitted neutrons showed an axial translation of the neutron source corresponding to velocities up to 2 × 108 cm/sec; this correlates with the nonsimultaneous pinching of the noncylindrical plasma along the axis. Plasma densities of ∼ 2 × 1020cm−3 and ion temperatures of 2 keV were consistent with observed neutron yields of 1010 and pulse widths of 60 nsec. X-ray intensity measurements were made for x-ray energies of 7 < Ep < 30 keV and showed an Ep−2 dependence which does not agree with plasma bremsstrahlung, but appears to result from anode bombardment of axially accelerated electrons with energies > 200 keV. The line radiation corresponded to that of fairly cold ions.
No takes yet. Share an insight, caveat, or question.
Bernstein et al. (1969) studied this question.