Answers are grounded in this paper and cite their sources.
The plasma parameters temporal evolution of a 30 W-class Vacuum Arc Thruster equipped with a Ni-Cr cathode is examined in the far-field region of the plasma jet. Measurements have been performed 20 cm downstream of the arc region where the plasma is created. The thruster operated at 1 Hz with 25 μ s duration current pulses. The maximum current intensity reaches 4000 A about 8 μ s after the discharge ignition. The change in the electron density, electron temperature and plasma potential during the short high-current pulse has been obtained by means of time-resolved Langmuir probe measurements. A time-of-flight technique based on a planar probe has been used to determine the mean ion velocity in the plasma jet. In addition, a Faraday cup allowed the determination of the ion current density. The electron density peaks at ∼ 8×10 17 m −3 at 12 μ s. The electron temperature is above 25 eV at 7 μ s and then it stabilizes around 5 eV. Several ion populations are identified. The lowest ion mean velocity amounts to 20 km/s. Interestingly, combining all data allows to assess the ion mean electrical charge and its temporal behavior. The mean charge reaches 12 a few μ s after ignition. It decays quickly afterwards and stays unchanged at 2 beyond 10 μ s. Analysis of all the results support the idea of two distinct plasma discharge regimes.
No takes yet. Share an insight, caveat, or question.
Michaux et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: