Answers are grounded in this paper and cite their sources.
Insulator sleeves of different lengths were used at the closed end of the coaxial electrode assembly of the 3.3 kJ United Nation University-International Centre for Theoretical Physics (UNU-ICTP) plasma focus device to investigate soft x-ray (SXR) (900–1550 eV) yield for different filling gas pressures of neon. The time and space resolved SXR emission characteristics were investigated using a multi-channel diode x-ray spectrometer and a CCD based pinhole imaging camera. At pressures below 6 mbar, the average SXR yield was also found to increase with increasing sleeve length from 19 to 22 mm. A further increase in insulator sleeve length to 25 mm, however, decreased the SXR yield. At pressures above 6 mbar, the SXR yields were almost the same for insulator sleeves of different lengths. The UNU-ICTP plasma focus device is found to be best optimized for neon SXR production with a 22 mm insulator sleeve at 4 mbar filling gas pressure, with the highest average yield of 8.2 J per shot, for which the conversion efficiency is about 0.25%. For this sleeve length, even the average yield at 2 or 6 mbar pressure was comparable with the maximum yield of a 25 mm sleeve.
No takes yet. Share an insight, caveat, or question.
Rawat et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: