Answers are grounded in this paper and cite their sources.
A very powerful method to measure the parameters of a one-section Coupled Transmission Line (CTL) coupler is presented. Three transmission measurements at the frequency of maximum coupling is sufficient to give the even- and odd-mode impedances (Z/sub e/,Z/sub 0/) and the even- and odd-mode lengths (Theta/sub e/,Theta/sub 0). Explicit equations are presented for the necessary calculations. Data for some stripline couplers measured with the new method are presented. The data show a very significant length difference between the even and odd modes, although boards with the same dielectric constant (measured according to the MIL standard) were used. Improved dielectric-constant measurement techniques for thin boards have been developed. The presented methods give more relevant information of dielectric constant and Q value of the thin boards. A new method for wide-band improvement of CTL-coupler directivity when Theta/sub e/ /spl ne/ Theta/sub 0/ has been developed. The theory is presented with all necessary equations and it covers both Theta/sub e/ > Theta/sub 0/ (microstrip) and Theta/sub e/ < Theta/sub 0/. The new method makes use of short compensating sections in the coupler to achieve a directivity pole at an arbitrary frequency. The wanted bandwidth determines the optimum location of the pole. Several examples with design data are given.
No takes yet. Share an insight, caveat, or question.
S. Rehnmark (1977) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: