Specific contact resistances measured at elevated temperatures for Ni ohmic contacts to 6H-SiC were reported. The specific contact resistances were measured with the linear transmission line method at both room temperature and at 500 °C and yielded values <5×10−6 Ω cm2 at both temperatures. The trend shows a decreasing contact resistance at higher temperatures. The annealed metal film is a nickel silicide with substantial mixing of C throughout the silicide layer.
No takes yet. Share an insight, caveat, or question.
Crofton et al. (1995) studied this question.