Visible/near-infrared spectroscopy is widely used for non-destructive fruit quality detection, but the high cost of spectrometers (400–1100 nm range) in sorting equipment limits its accessibility. This study proposes a dual-channel co-spectroscopy method to address this issue. Using apples’ soluble solids content as the research target, a dual-channel platform was constructed to optimize parameters for full-transmission spectral signal acquisition. Spectral data were collected using dual channels (400–700 nm and 700–1100 nm bands, separated by filters) and a single channel (400–1100 nm range). Preprocessing methods (MSC, SNV, FD, SD, SG) and feature extraction algorithms (CARS, SPA, UVE) were applied, followed by PLSR modeling. The dual-channel method with Raw spectrum + FD + CARS + PLSR achieved optimal results, with R2v = 0.88, RMSEP = 0.39 for the 400–700 nm band, and R2v = 0.94, RMSEP = 0.33 for the 700–1100 nm band. The single-channel method with Raw spectrum + MSC + CARS + PLSR achieved R2v = 0.90, RMSEP = 0.36. These findings validate dual-channel co-spectroscopy as a cost-effective, accurate solution for non-destructive fruit quality detection, providing a practical approach to reduce spectrometer costs and enhance sorting system efficiency.