Why the study?
Does incorporating R2 modeling improve the accuracy of accelerated skeletal muscle fat fraction measurements in muscular dystrophy?
Does incorporating R2 modeling improve the accuracy of accelerated skeletal muscle fat fraction measurements in muscular dystrophy?
Incorporating R2 modeling in accelerated MRI acquisitions prevents systematic errors in muscle fat fraction measurements without losing precision.
Answers are grounded in this paper and cite their sources.
May enhance accuracy of accelerated fat-fraction MRI in muscular dystrophy; leaves open prospective validation before clinical adoption.
Purpose To investigate the effect of R2* modeling in conventional and accelerated measurements of skeletal muscle fat fraction in control subjects and patients with muscular dystrophy. Materials and Methods Eight patients with Becker muscular dystrophy and eight matched control subjects were recruited with approval from the Newcastle and North Tyneside 2 Research Ethics Committee and with written consent. Chemical-shift images with six widely spaced echo times (in 3.5-msec increments) were acquired to correlate R2* and muscle fat fraction. The effect of incorporating or neglecting R2* modeling on fat fraction magnitude and variance was evaluated in a typical three-echo protocol (with 0.78-msec increments). Accelerated acquisitions with this protocol with 3.65×, 4.94×, and 6.42× undersampling were reconstructed by using combined compressed sensing and parallel imaging and fat fraction maps produced with R2* modeling. Results Muscle R2* at 3.0 T (33-125 sec(-1)) depended on the morphology of fat replacement, the highest values occurring with the greatest interdigitation of fat. The inclusion of R2* modeling removed bias, which was greatest at low fat fraction, but did not increase variance. The 95% limits of agreement of the accelerated acquisitions were tight and not degraded by R2* modeling (1.65%, 1.95%, and 2.22% for 3.65×, 4.94×, and 6.42× acceleration, respectively). Conclusion Incorporating R2* modeling prevents systematic errors in muscle fat fraction by up to 3.5% without loss of precision and should be incorporated into all muscular dystrophy studies. Fat fraction measurements can be accelerated fivefold by using combined compressed sensing and parallel imaging, modeling for R2* without loss of fidelity.
No takes yet. Share an insight, caveat, or question.
Loughran et al. (2015) studied this question.