Why the study?
Does transcatheter aortic valve replacement alter ventricular-aortic interaction and central augmentation index in patients with aortic valve stenosis?
Observational (n=33)
Does transcatheter aortic valve replacement alter ventricular-aortic interaction and central augmentation index in patients with aortic valve stenosis?
TAVR acutely alters ventricular-aortic interaction and decreases the central augmentation index, challenging its interpretation as a solely vascular measure in aortic stenosis.
Challenges AIx interpretation as solely vascular in aortic stenosis; hypothesis-generating for TAVR effects on ventricular-aortic interaction, needing randomized confirmation.
Transcatheter aortic valve replacement (TAVR) is increasingly used to treat severe aortic stenosis (AS) patients. However, little is known regarding the direct effect of TAVR on the ventricular-aortic interaction. In the present study, we aimed to investigate changes in central hemodynamics after successful TAVR. We retrospectively examined 33 cases of severe AS patients (84 ± 6 yr) who underwent TAVR. Invasive measurements of left ventricular and aortic pressures as well as echocardiographic aortic flow were acquired before and after TAVR (maximum within 5 days). We examined alterations in key features of central pressure and flow waveforms, including the aortic augmentation index (AIx), and performed wave separation analysis. Arterial parameters were determined via parameter-fitting on a two-element Windkessel model. Resolution of AS resulted in direct increase in the aortic systolic pressure and maximal aortic flow (131 ± 22 vs. 157 ± 25 mmHg and 237 ± 49 vs. 302 ± 69 mL/s, P < 0.001 for all), whereas the ejection duration decreased (P < 0.001). We noted a significant decrease in the AIx (from 42 ± 12 to 19 ± 11%, P < 0.001). Of note, the arterial properties remained unchanged. There was a comparable increase in both forward (61 ± 20 vs. 77 ± 20 mmHg, P < 0.001) and backward (35 ± 14 vs. 42 ± 10 mmHg, P = 0.013) pressure wave amplitudes, while their ratio, i.e., the reflection coefficient, was preserved. Our results highlight the impact of TAVR on the ventricular-aortic interaction by affecting the amplitude, shape, and related attributes of the aortic pressure and flow pulse and challenge the interpretation of AIx as a solely vascular measure in AS patients.NEW & NOTEWORTHY Transcatheter aortic valve replacement (TAVR) is linked with an immediate increase in aortic systolic blood pressure and maximal flow, as well as steeper aortic pressure and flow wave upstrokes. After TAVR, the forward wave pumped by the heart is enhanced. Although the arterial properties remain unchanged, the central augmentation index (AIx) is markedly decreased after TAVR. This challenges the interpretation of AIx as a solely vascular measure in patients with aortic valve stenosis.
No takes yet. Share an insight, caveat, or question.
Pagoulatou et al. (2020) conducted an observational in Severe aortic stenosis (n=33). Transcatheter aortic valve replacement (TAVR) vs. Pre-TAVR baseline was evaluated on Aortic systolic pressure (mmHg) (p=<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: