Why the study?
Minimizing pre-analytical variation is desirable to achieve reproducible low hs-cTn concentrations for accelerated diagnostic pathways, and whether BD Barricor tubes provide more reproducible hs-cTnT results than plasma separator tubes at concentrations <= 20 ng/L was unknown.
Does the use of BD Barricor blood collection tubes reduce pre-analytical variation in hs-cTnT results at concentrations ≤ 20 ng/L compared to plasma separator tubes?
Does the use of BD Barricor blood collection tubes reduce pre-analytical variation in hs-cTnT results at concentrations ≤ 20 ng/L compared to plasma separator tubes?
BD Barricor blood collection tubes significantly reduce pre-analytical variation and improve reproducibility of low-concentration hs-cTnT measurements compared to standard plasma separator tubes.
Answers are grounded in this paper and cite their sources.
Barricor tubes were associated with lower hs-cTnT pre-analytical variation; hypothesis-generating and should not yet change practice.
OBJECTIVE: Reproducible low troponin concentrations from high-sensitivity troponin (hs-cTn) assays are paramount to accurate risk determination in the accelerated diagnostic pathway. Total variation consists of pre-analytical, analytical and biological components. While analytical and biological variations cannot be readily modifiable, minimizing pre-analytical variation is desirable and potentially attainable. The BD Barricor collection tube has previously been demonstrated to reduce pre-analytical variation in test results. The goal of the study is to determine whether BD Barricor tubes provide more reproducible hs-cTnT results compared to plasma separator tubes (PST) at concentrations ≤ 20 ng/L. METHODS: Paired intra-patient hs-cTnT results collected less than 1 h apart in the emergency department were retrospectively analyzed from nine urban hospitals which primarily use either PST (n = 336 pairs) or Barricor (n = 327 pairs) collection tubes for troponin. Total variation of the replicated measurements was calculated for hs-cTnT ≤ 20 ng/L. The numbers of paired intra-patient samples were grouped based on decisive absolute delta thresholds as indicated by the European Society of Cardiology 0/1 h algorithm; delta < 3 ng/L, 3-4 ng/L, ≥5 ng/L. RESULTS: The total testing variation for hs-cTnT collected in PST is 14.8 % while Barricor is 8.6 % for hs-cTnT ≤ 20 ng/L. The proportion of delta values < 3 ng/L between the intra-patient replicates is 80.4 % (95 % CI: 75.7-84.5 %) in PST compared to 95.4 % (95 % CI: 92.5-97.4 %) in Barricor (p < 0.001). Median time for serial sampling in PST is 41 min (IQR:18-53) and Barricor is 45 min (IQR 23-54). CONCLUSION: The use of Barricor tubes demonstrated reproducible and less variable hs-cTnT replicates at concentration ≤ 20 ng/L when compared to a hospital that does not use Barricor tubes.
No takes yet. Share an insight, caveat, or question.
Tsui et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: