Why the study?
A vascular access blood flow to cardiac output ratio greater than 0.3 increases the risk of high-output heart failure, but the associated characteristics and risk factors over one year needed evaluation.
What are the risk factors and hemodynamic consequences over one year of a high Qa/CO ratio in hemodialysis patients?
What are the risk factors and hemodynamic consequences over one year of a high Qa/CO ratio in hemodialysis patients?
High Qa/CO ratios in hemodialysis patients are associated with significant cardiac adaptations including increased cardiac output over one year, highlighting the risk of high-output heart failure.
High Qa/CO may signal rising cardiac output risk in hemodialysis; leaves open need for prospective trials before changing access practices.
Background: A vascular access blood flow (Qa) to cardiac output (CO) ratio greater than 0.3 increases the risk of high-output heart failure (HOHF). This study analyzed the characteristics and risk factors associated with a high Qa/CO ratio and effective CO (COef) in these patients over one year. Methods: This prospective study enrolled 142 hemodialysis (HD) patients, divided by the Qa/CO ratio. Baseline and one-year hemodynamics were measured: volume by bioimpedance, CO by echocardiography, Qa and brachial flow by transonic and ultrasound. Risk factors for HOHF were analyzed using receiver operating characteristic (ROC) curves and multivariable regression. Results: The study population was 66% male, mean age of 65, with 71% using arteriovenous fistulae (AVF) for vascular access. In the high Qa/CO group, cases of younger ages (62 vs. 67 years, p = 0.040) with upper arm access (73.1% vs. 32.8%, p < 0.001) were more prevalent, and diastolic blood pressure (DBP) was higher (76.8 ± 15.1 vs. 66.7 ± 14.4 mmHg, p = 0.002). Independent risk factors for high Qa/CO were elevated DBP (odds ratio [OR]: 1.080; 95% confidence interval [CI]: 1.028–1.134), upper arm access (OR: 8.113; 95% CI: 1.842–35.741), low resistive index (RI) (OR: 0.000; 95% CI: 0.000–0.417), and COef (OR: 0.164; 95% CI: 0.065–0.416). After one year, the high Qa/CO group showed significant increases in CO and COef (4.82 ± 1.25 L/min vs. 6.16 ± 2.05 L/min, p = 0.007, and 2.84 ± 0.95 L/min to 4.40 ± 1.89 L/min, p = 0.001, respectively). A baseline Qa cutoff value of 1.4 L/min demonstrated high diagnostic efficacy in identifying the high Qa/CO group. Conclusions: High Qa/CO ratios increase overt HOHF risk due to cardiac strain. This study reveals AV access-driven cardiac adaptations in patients with high Qa/CO and low COef, emphasizing the necessity for ongoing clinical and hemodynamic monitoring.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: