Why the study?
Pulmonary vein isolation for PAF can be performed with cryoballoon ablation or radiofrequency ablation, but changes in P-wave parameters between these methods needed comparison.
Does radiofrequency ablation compared to cryoballoon ablation result in different P-wave parameter changes or freedom from AF at 12 months in patients with paroxysmal atrial fibrillation?
Does radiofrequency ablation compared to cryoballoon ablation result in different P-wave parameter changes or freedom from AF at 12 months in patients with paroxysmal atrial fibrillation?
Answers are grounded in this paper and cite their sources.
Radiofrequency and cryoballoon ablation for paroxysmal atrial fibrillation result in similar P-wave parameter changes and 12-month efficacy, with increased corrected P-wave duration predicting ablation failure in both modalities.
Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) can be performed using one-shot cryoballoon ablation (cryo) or point-by-point radiofrequency ablation (RF). This study compares the changes in P-wave parameters between both ablation methods. This single-centre retrospective study included contact force RF and second-generation cryo for PAF between 2018 and 2019. Procedure success was defined by freedom of ECG-documented AF at 12 months. Digital 12‑leads ECGs with 1–50 hertz bandpass filters were monitored directly during the procedure. Corrected P-wave duration (PWDc), P-wave amplitude (PWV), P-wave dispersion (PWDisp), and P-wave terminal force in V1 (PTFV1) were measured and compared between RF and cryo. Additional ablations were excluded. The final analysis included 226 patients, and the freedom of AF rate was similar at the 12-month follow-up (76 % vs 74 %, P = 0.12). PWDc and PWV increased and decreased, respectively in RF and cryo. PTFV1 decreased in RF (−3.3 mm.s to −4.6 mm.s, P < 0.001) and cryo (−3.4 mm.s to −5.3 mm.s, P = 0.002). There were similar changes after RF and cryo in PWDc (F 11, 1032 = 0.80, P = 0.85), PWV (F 11, 1032 = 0.19, P = 0.06), and PWDisp (F 11, 1032 = 0.16, P = 0.34) and PTFV1 ( P = 0.39). Increased PWDc was correlated with failure of RF (hazard ratio [2.3], 95 % confidence interval [CI]: 1.4–5.9, p = 0.01) and cryo (HR: 2.1, 95 % CI (1.3–4.6), p = 0.02). Results were similar when patients on antiarrhythmic drugs were excluded. RF and cryo caused similar freedom of AF rate at 12 months in PAF and similar P-wave parameter changes. Increased PWDc was correlated with RF and cryo failure.
No takes yet. Share an insight, caveat, or question.
Antoun et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: