Why the study?
New-onset conduction abnormalities after TAVR are linked to rehospitalization and mortality, but available clinical predictors were sparse.
What are the periprocedural predictors of new-onset conduction abnormalities after transcatheter aortic valve replacement?
What are the periprocedural predictors of new-onset conduction abnormalities after transcatheter aortic valve replacement?
Computed tomography assessment of membranous septal anatomy and implantation depth (∆MSID) can predict new-onset conduction abnormalities after TAVR, which are associated with worse clinical outcomes.
Answers are grounded in this paper and cite their sources.
∆MSID and PR interval may aid conduction risk stratification in TAVR; hypothesis-generating for anatomy-guided implantation to improve outcomes.
BACKGROUND: New-onset conduction abnormalities (CAs) following transcatheter aortic valve replacement (TAVR) are associated with hospital rehospitalization and long-term mortality, but available predictors are sparse. This study sought to determine clinical predictors of new-onset left bundle branch block (LBBB) and new permanent pacemaker (PPM) implantation in patients undergoing TAVR. METHODS AND RESULTS: We enrolled 290 patients who received SAPIEN 3 (Edwards Lifesciences, Irvine, CA, USA; n=217) or Evolut R (Medtronic, Minneapolis, MN, USA; n=73) from a prospective registry at Nouvel Hôpital Civil, Strasbourg, France between September 2014 and February 2018. Of 242 patients without pre-existing LBBB, 114 (47%) experienced new-onset LBBB and/or new PPM implantation. A difference between membranous septal length and implantation depth (∆MSID) was the only predictor of CAs for both types of valves. In the multivariate analysis, PR interval and ∆MSID remained as sole predictors of CAs. The risk for adverse clinical events, including all-cause death, myocardial infarction, stroke, and heart failure hospitalization, was higher for patients with CAs as compared with patients without CAs (hazard ratio: 2.10; 95% confidence interval: 1.26 to 3.57; P=0.004). CONCLUSIONS: Computed tomography assessment of membranous septal anatomy and implantation depth predicted CAs after TAVR with new-generation valves. Future studies are required to identify whether adjustment of the implantation depth can reduce the risk of CAs and adverse clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Matsushita et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: