This is the authors' abstract. We don't add key points for this paper.
Acute kidney injury (AKI) is a common clinical syndrome characterized by abnormal renal function and structure. Microcirculatory perfusion disorders and inflammatory responses are critical pathophysiologies of AKI. Recently, ultrasound molecular imaging has been considered a valuable tool for preclinical and clinical diagnostics that can sensitively target histological structures of interest, particularly in evaluating renal microcirculation. The purpose of this study was to explore a lipid microbubble (MB E-selectin ) that targets E-selectin molecules expressed on the activated endothelium and to perform ultrasound molecular imaging for the kidney in cisplatin-induced AKI in rats. Using freeze-drying methods, three formular nontargeted microbubbles (NMBs-1, NMBs-2, NMBs-3) were prepared, and three corresponding MB E-selectin suspensions (MB E-selectin -1, MB E-selectin -2, MB E-selectin -3) were constructed via maleimide–thiol conjugation chemistry. The results revealed that the physicochemical characteristics of three NMBs and MB E-selectin suspensions were usable for intravenous injection as ultrasound contrast agents (UCAs), and the anti-E-selectin antibody successfully conjugated to the lipid shell surface of the bubbles in three MB E-selectin suspensions, which could bind specifically to E-selectin molecules expressed on human umbilical vein endothelial cells (HUVECs) treated with tumor necrosis factor-alpha (TNF-α). During ultrasound imaging for the kidney in the cisplatin-induced AKI model, the time-to-peak (TTP) and area under the curve (AUC) of the MB E-selectin -2 suspension significantly increased, but the wash-in rate (WIR) and wash-out rate (WOR) significantly decreased compared with those of the NMBs-2 suspension or the control group. The normalized differential targeted enhancement (NdTE) of the MB E-selectin -2 suspension was significantly greater than that of the NMBs-2 suspension in the model group, as was the residual-to-saturation ratio (RSR) at 8 min. In conclusion, we successfully prepared a novel MB E-selectin suspension carrying an anti-E-selectin antibody that can be used for intravenous injection and can enhance ultrasound imaging of the kidney as a UCA, particularly in a cisplatin-induced AKI model. Ultrasound molecular imaging of the MB E-selectin suspension may be helpful for evaluating renal microcirculation or injury in AKI diseases.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Si et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: