Increasing penicillin resistance and the initial recognition of resistance to extended-spectrum cephalosporins among Streptococcus pneumoniae isolates have placed greater emphasis on accurate methods for susceptibility testing of clinical isolates. This study has evaluated the use of the E test (AB Biodisk NA, Piscataway, N.J.) for the detection of penicillin and cefotaxime resistance among 147 pneumococcal clinical isolates in three geographically separate laboratories. These included 42 penicillin-resistant (MIC, > or = 2 micrograms/ml) and 14 cefotaxime-resistant (defined here as an MIC of > or = 2 micrograms/ml) isolates. E test strips were applied to the surface of Mueller-Hinton sheep blood agar plates and incubated at 35 degrees C in 5% CO2 for 20 to 24 h. E test MICs were compared with MICs determined with lysed horse blood-supplemented Mueller-Hinton broth in a microdilution format as recommended by the National Committee for Clinical Laboratory Standards. Penicillin MICs agreed within one log2 dilution for 136 of 147 (92.5%) isolates, and cefotaxime MICs agreed within one log2 dilution for 142 of 147 (96.6%) isolates. No very major or major interpretive errors occurred with either penicillin or cefotaxime E test MIC results. There were 9.5 and 5.4% minor interpretive category errors with penicillin and cefotaxime E test MICs, respectively. These data indicate that the E test represents a convenient and reliable method for the detection of penicillin or cephalosporin resistance in pneumococci.
No takes yet. Share an insight, caveat, or question.
Jorgensen et al. (1994) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: