This is the authors' abstract. We don't add key points for this paper.
The thermal conductivity data for krypton and xenon are reported in the temperature range 350–1500°K. The conductivity column method is used for which all the necessary details are given in an earlier publication [J. Chem. Phys. 48, 5662 (1968)]. The new data agree well with the available data but the latter are limited to the highest temperature of 579°K only. Thus, the reported data above 579°K are novel. The measured conductivity values are well correlated by a quadratic polynomial in temperature over the entire range. The estimated uncertainty of our measurements is about ± 2%. The measured values are compared with the predictions of theory and also used for generating the viscosity and diffusion coefficients.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Saxena et al. (1969) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: