Magnetoelectric laminate composites of piezoelectric/magnetostrictive materials were prepared by stacking and bonding together a PZT disk and two layers of Terfenol‐D disks with different directions of magnetostriction. These composites were studied to investigate (i) dependence on the magnetostriction direction of the Terfenol‐D disk and (ii) dependence on the direction of the applied ac magnetic field. Three different types of assemblies were prepared by using two types of disks: one with magnetostriction along the radial direction, the other with magnetostriction along the thickness direction. The maximum magnetoelectric voltage coefficient (d E /d H ) of 5.90 V/cm·Oe was obtained for a design where the composite was made by two Terfenol‐D layers with a radial magnetostriction direction.
No takes yet. Share an insight, caveat, or question.
Ryu et al. (2001) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: