Answers are grounded in this paper and cite their sources.
IN connection with a study of the use of diathermy in the treatment of general paresis (1) we were enabled to make a comparison of the effects of hyperthermia induced by this method with the results of exposure to a vacuum tube oscillator. The narrow frequency range of the diathermy machine and the physical limitations to its use have restricted its application biologically. The modern development of the vacuum tube oscillator has opened up a new field, since its use has made possible the investigation of frequencies ranging from 1 million to 158 million and more cycles per second. Very little analytical work has been done on the biological effects of these currents, but it is believed that they differ fundamentally from those produced by any other type of electric current. Our first experiments were with the diathermy current ; the second part of the work was done with the vacuum tube oscillator.1 The diathermy was tried on human subjects (paretics) and on dogs. Experiments on Humans (1).—The successful treatment with diathermy depends on certain mechanical factors necessary to produce a rise of temperature, to maintain it, and to prevent burns in the patient. The prime requisites are properly constructed electrodes, a machine powerful enough to deliver sufficient energy, and proper insulation of the subject. The electrodes must have a long edge because the current tends to concentrate along the edges. Fenestrated electrodes accomplish this. Furthermore, when large surfaces of the body are subjected to heavy doses of diathermy current, between 4,000 and 6,000 milliamperes, varying resistances are encountered, depending largely upon thickness. In order to force 6,000 ma. through the body with safety the electrodes must be as large as possible. The entire back must be covered by one electrode and the entire chest and abdomen by another. The current was applied in such a manner that the maximum temperature (103°–104°F.) was reached after from 3 to 4½ hours. Rectal and mouth temperatures were taken every fifteen minutes. Blood was drawn just before the current was applied, and immediately after the treatment. For the carbon dioxide determinations the blood was collected under a neutral mineral oil. Results of the Blood Analyses.—Determinations were made of blood chlorides, serum calcium, CO2 combining power of the plasma, non-protein nitrogen, and uric acid. Six patients in all were examined throughout the entire course of treatment. Nonprotein nitrogen and uric acid were determined in only one patient in a course of ten treatments. Blood Chlorides: Determined by the Van Slyke modification of the Whitehorn method. There was about a 10 per cent increase, which may have been due to the increased concentration of the blood. Serum Calcium: Determined by the Clark-Collip modification of the Kramer-Tisdall method.
No takes yet. Share an insight, caveat, or question.
B. Mortimer (1931) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: