Answers are grounded in this paper and cite their sources.
An optical fiber sensor with a Fabry–Perot cavity is described, in which a polydimethylsiloxane layer is bounded by two aluminum mirrors at the end of an optical fiber. The interference response of the sensor was evaluated in both the spectral and time domains. For the fabricated sensor, interference fringes with a visibility of ∼14 dB were achieved in air in the spectral domain at a final cavity length of ∼34 μm. The sensor was tested in acetone vapor and in liquid carvone, where a significant red shift of the interference fringes was observed in the spectral domain, along with different swelling/deswelling dynamics in the time domain. The sensor configuration is compact and reusable, and its parameters can be readily optimized for different target analytes and environments.
No takes yet. Share an insight, caveat, or question.
Martinček et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: