The fact that the presence of a film too thin to be visible could profoundly modify the contact p.d. between any pair of metals was first recorded by J. Erskine Murray (1898).Murray used the method of measurement introduced by Lord Kelvin (1898).This method depends on the fact that if the plates of a condenser are made of different metals they will normally contain a charge sufficient to maintain an e.m.f.across the condenser equal to the contact p.d. of the two metals, and that if the plates of the condenser are separated and the capacity thereby changed, a current must necessarily flow in order to maintain an e.m.f.equal to contact p.d.With the modern realisation of the tenacity with which metal surfaces hold primary gaseous films and the great difficulty with which these films are removed and a pure metal surface thus produced, we now prefer some method of measurement in which metal filaments take the place of Kelvin's plates.These metal filaments can of course readily be outgassed through heating to a high temperature by means of an electric current ; provided the metals chosen have sufficiently high melting points.Special methods have been described in the literature for dealing with the more fusible metals by depositing them over a core of a more infusible one.
No takes yet. Share an insight, caveat, or question.
Richard Charles Leslie Bosworth (1946) studied this question.